VOLTECH AC INTERFACE FEATURES AND CAPABILITIES
BOOST THE CAPABILITY OF YOUR AT SERIES FOR HIGH-POWER APPLICATIONS
VOLTECH AC INTERFACE FEATURES
- Extends the AT3600/AT5600 test range using third-party AC sources
- Works with high-power external AC sources (up to 600 V @ 10 A, 20 Hz–5 kHz)
- Works with step-up/step-down transformers (0–600 V, <40 W)
- Automatic source control for faster tests and improved operator safety
- Seamless integration with AT test programs
- Compact design fits into the AT rear fixture bay
- Boosts the internal generator using step-up/step-down transformers
- Enables a plug-in Current Transformer for accurate measurement of very low currents, even when energizing components at high AC voltages

TEST CAPABILITIES
Test | Description | Measurement Range | Test Signal | Test Frequency | Basic Accuracy |
---|---|---|---|---|---|
VOCX | Open Circuit Voltage (External Source) | 100 mV to 650 V * | 1 V to 600 V | 20 Hz to 5 kHz ** | 0.10% |
MAGX | Magnetizing Current (External Source) | 50 mA to 10 A * | 1 V to 600 V | 20 Hz to 5 kHz ** | 0.10% |
WATX | Wattage (External Source) | 100 mW to 6 kW * | 1 V to 600 V | 20 Hz to 5 kHz ** | 1.00% |
STRX | Stress Wattage (External Source) | 100 mW to 6 kW | 1 V to 600 V | 20 Hz to 5 kHz ** | 1.00% |
NOTES:
* 40 W when using ACIF with a step-up/step-down transformer; 6 kW max when using ACIF with external AC power.
** Depends on the type of external source.
GENERAL SPECIFICATIONS
Size | 290mm x 110mm x 32mm |
---|---|
Weight | Approx. 750g |
Operating temperature | 0 to 40°C |
Storage temperature | –40 to 70°C |
Humidity | 10 to 90% RH, non-condensing |