      Tests and Specifications

      The AT5600 is capable of performing over 40 different test types.
      In addition to this you can also write test programs (basically a pre-programmed sequence of tests) with up to 150 different steps.
      This extends the scope from the AT3600, which only allowed 65 different steps.
      The following page summarizes the tests available for the AT5600 tester, and indicates where and why they might be used.
      A complete description of each test, its allowed signal levels and measurement accuracy can be found in the user manual.

      The tester is available to purchase in one of two versions
      AT5600 GOLD
      - all tests are enabled at point of shipment

      AT5600 STANDARD
      - you choose which 14 tests you would like enabled in the unit.


      Additional tests can be purchased at any later date, and easily added to the tester by entering a simple keycode via the front panel.
      All tests are calibrated and tested at point of sale, even if not purchased with the initial unit, so there is no need to return the unit if you wish to add extra tests later.

      Tests Available

      1. Low Voltage Tests

      TEST DESCRIPTION Main Application Winding Tested Reason for Test
      CTY Continuity All transformers All windings Properly installed fixture
      R DC Resistance All transformers All windings Properly installed fixture. Correct wire used. Integrity of terminations
      LS Inductance (Series circuit) Most transformers, but usually not line frequency transformers One winding, usually the primary Correct primary turns. Right grade of core material. Core correctly assembled
      LP Inductance (Parallel circuit) Most transformers, but usually not line frequency transformers One winding, usually the primary Correct primary turns. Right grade of core material. Core correctly assembled
      QL Quality Factor Most transformers, but usually not line frequency transformers One winding, usually the primary Right grade of core material. Core correctly assembled. Check for shorted turns
      RLS Equivalent Series Resistance Most transformers, but usually not line frequency transformers One winding, usually the primary Right grade of core material. Core correctly assembled. Check for shorted turns
      RLP Equivalent Parallel Resistance Most transformers, but usually not line frequency transformers One winding, usually the primary Right grade of core material. Core correctly assembled. Check for shorted turns
      D Dissipation Factor Most transformers, but usually not line frequency transformers One winding, usually the primary Right grade of core material. Core correctly assembled. Check for shorted turns
      LL Leakage Inductance SMPS transformers Communication transformers Others as applicable Selected windings Check windings have been installed in the correct position relative to the core
      C Interwinding Capacitance High frequency transformers. Isolating transformers Selected windings Check winding positioning.Check insulation thickness between windings
      TR Turns Ratio and Phasing Most transformers, but usually not line frequency transformers All windings Check windings have correct turns and phasing
      TRL Turns Ratio by Inductance As with Turns Ratio but used where there is poor flux linkage between windings. All windings Check windings have correct turns and phasing
      LVOC Low Voltage Open Circuit Usually line frequency transformers All other windings Correct secondary turns. Correct phasing
      IR Insulation Resistance All transformers Between selected windings Winding isolation check where safety is not involved
      LSB Inductance with Bias Current (Series Circuit) Transformers for use in applications where passing significant (dc) bias current is part of the normal operation One winding Correct number of turns. Right grade of core material. Core correctly assembled.
      LPB Inductance with Bias Current (Parallel Circuit) Transformers for use in applications where passing significant (dc) bias current is part of the normal operation One winding Correct number of turns. Right grade of core material. Core correctly assembled.
      OUT Output To User Port     Allows the AT to perform external switching as part of the test program.
      R2 DC Resistance Match SMPS, audio & telecom All windings Checks matching between windings
      L2 Inductance Match SMPS, audio & telecom transformers All windings Checks matching between windings
      C2 Capacitance Match SMPS, audio & telecom transformers All Windings Checks correct winding position on bobbin
      GBAL General Longitudinal Balance Audio & telecom transformers Selected Windings Checks common mode rejection ratio
      LBAL Longitudinal Balance Audio & telecom transformers Selected Windings Checks common mode rejection ratio
      ILOS Insertion Loss Audio & telecom transformers Selected Windings Checks losses within the transformer
      RESP Frequency Response Audio & telecom transformers Selected Windings Checks losses over a range of frequencies
      RLOS Return Loss Audio & telecom transformers Selected Windings Checks losses returned by a transformer
      Z Impedance Audio & telecom transformers Selected Windings Checks impedance at a given frequency
      ZB Impedance + bias Audio & telecom transformers Selected Windings Checks impedance at a given frequency
      ANGL Impedance Phase Angle Audio & telecom transformers Selected Windings Finds phase shift between Voltage and Current on a winding.
      PHAS Interwinding Phase Test Audio & telecom transformers Selected Windings Measures phase shift between a pair of windings

      2. High Voltage Tests

      TEST DESCRIPTION Main Application Winding Tested Reason for Test
      HPDC Hi-Pot (DC) All transformers especially those used for safety insulation Between selected windings usually primary to secondary, screens and core High voltage safety insulation
      HPAC Hi-Pot (AC) All transformers especially those used for safety insulation Between selected windings usually primary to secondary, screens and core High voltage safety insulation
      ACRT Hi-Pot Ramp (AC) All transformers especially those used for safety insulation Between selected windings usually primary to secondary, screens and core High voltage safety insulation
      DCRT Hi-Pot Ramp (DC) All transformers especially those used for safety insulation Between selected windings usually primary to secondary, screens and core High voltage safety insulation
      ACVB Voltage Breakdown (AC) Transformers with MOV fitted Between selected windings usually primary to secondary, screens and core High voltage safety insulation
      DCVB Voltage Breakdown (DC) Transformers with MOV fitted Between selected windings usually primary to secondary, screens and core High voltage safety insulation
      WATT Wattage 50Hz Iron core transformers One winding Correct core material. Properly assembled
      ILK Leakage Current Test Medical applications Between Primary and Secondary Windings Checks for a common mode current due to capacitance
      STRW Stress Wattage Line frequency & High Frequency Transformers One Winding (Usually the primary) Checks integrity of inter-turn insulation, the magnetic material and joints
      SURG Surge Stress Test All transformers, especially those using fine wire Selected windings To identify shorted turns
      MAGI Magnetising Current Usually line frequency transformers One winding, usually the primary Correct primary turns Correct core material properly assembled
      VOC Open Circuit Voltage Usually line frequency transformers All other windings Correct secondary turns. Correct phasing

      3. DC1000 Tests

      These tests allow the AT5600 to automatically control a Voltech DC1000 for testing transformers with 0-25ADC Bias current applied (or up to 500A DC with 20 DC1000s!)
      TEST DESCRIPTION Main Application Winding Tested Reason for Test
      LSBX Inductance with External Bias (Series Circuit) Wound components that usually carry a significant DC Bias current in normal operation. Selected Windings Checks number of turns, right grade of correctly assembled core material, where bias current is greater than LSB test can handle.
      LPBX Inductance with External Bias (Parallel Circuit) Wound components that usually carry a significant DC Bias current in normal operation. Selected Windings Checks number of turns, right grade of correctly assembled core material, where bias current is greater than LPB test can handle.
      ZBX Impedance with External Bias Audio & Telecom Selected Windings Checks impedance at a given frequency, while applying a greater bias current than is possible with ZB test.

      4. AC INTERFACE FIXTURE tests

      Allows the AT5600 to use the Voltech AC INTERFACE to interface with your own AC source, to extend test range to 600V @ 10A, 20Hz to 1MHz
      TEST DESCRIPTION Main Application Winding Tested Reason for Test
      MAGX MAGI (External Source) Usually line frequency transformers One winding, usually the primary Correct primary turns. Correct core material properly assembled.
      VOCX VOCX (External Source) Usually line frequency transformers All other windings Correct secondary turns. Correct phasing.
      WATX WATT (External Source) 50Hz Iron core transformers One winding Correct core material. Properly assembled.
      STRX STRW (External Source) Line frequency & High Frequency Transformers One Winding (Usually the primary) Checks integrity of inter-turn insulation, the magnetic material and joints.

      Test Range and Accuracy Specification

          USER ENTERED TEST DATA  
      TEST DESCRIPTION Measurement Range Test Signal Test Frequency Basic Acc.
        Low Voltage Tests
      CTY Continuity 10kΩ to 10MΩ n/a n/a n/a
      R DC Resistance 10uΩ to 10MΩ n/a n/a 0.10%
      LS Inductance (series circuit) 1nH to 1MH 1mV to 5V 20Hz-3MHz 0.05%
      LP Inductance (parallel circuit) 1nH to 1MH 1mV to 5V 20Hz-3MHz 0.05%
      QL Quality Factor 0.001 to 1000 1mV to 5V 20Hz-3MHz 0.50%
      D Dissipation Factor 0.001 to 1000 1mV to 5V 20Hz-3MHz 0.50%
      RLS Equivalent Series Resistance 10uΩ to 10MΩ 1mV to 5V 20Hz-3MHz 0.05%
      RLP Equivalent Parallel Resistance 10uΩ to 10MΩ 1mV to 5V 20Hz-3MHz 0.05%
      LL Leakage Inductance 1nH to 1kH 1mV to 5V 20Hz-3MHz 0.10%
      C Inter-winding Capacitance 100fF to 1mF 1mV to 5V 20Hz-3MHz 0.10%
      TR Turns Ratio and Phasing 1:100k to 100K:1 1mV to 5V 20Hz-3MHz 0.10%
      TRL Turns Ratio by Inductance 30:1 to 1:30 1mV to 5V 20Hz-3MHz 0.10%
      LVOC Low Voltage Open Circuit 1mV to 650V 1mV to 5V 20Hz-3MHz 0.10%
      LSB Inductance with Bias (Series) DC Bias 1nH to 1MH 1mV to 5V 20Hz-3MHz 0.05%
      LPB Inductance with Bias (Parallel) DC Bias 1nH to 1MH 1mV to 5V 20Hz-3MHz 0.05%
      R2 DC Resistance Match 1:1000 to 1000:1 n/a n/a 0.20%
      L2 Inductance Match 1:10000 to 10000:1 1mV to 5V 20Hz-3MHz 0.10%
      C2 Inter-winding Capacitance Match 1:1000 to 1000:1 1mV to 5V 20Hz-3MHz 0.20%
      GBAL General Longitudinal Balance 0db to 100dB 1mV to 5V 20Hz-3MHz 0.5dB
      LBAL Longitudinal Balance 0db to 100dB 1mV to 5V 20Hz-3MHz 0.5dB
      ILOS Insertion Loss 100 dB to -100dB 1mV to 5V 20Hz-3MHz 0.5dB
      RESP Frequency Response 100 dB to -100dB 1mV to 5V 20Hz-3MHz 1.0dB
      RLOS Return Loss 100 dB to -100dB 1mV to 5V 20Hz-3MHz n/a
      ZB Impedance, Impedance + Bias 1mΩ to 1MΩ 1mV to 5V 20Hz-3MHz 0.20%
      ANGL Impedance Phase Angle 360 deg to -360 deg 1mV to 5V 20Hz-3MHz 0.05 deg
      PHAS Inter-winding Phase Angle 360 deg to -360 deg 1mV to 5V 20Hz-3MHz 0.05 deg
      OUT Output to User Port n/a n/a n/a n/a
        High Voltage Tests
      HPAC Hi-Pot (AC) 10uA to 30mA 100V to 5kV 50Hz-1kHz 3.00%
      HPDC Hi-Pot (DC) 1uA to 3mA 100V to 7kV n/a 3.20%
      ACRT Hi-Pot Ramp (AC) 10uA to 5mA 100V to 5kV 50Hz-1kHz 3.00%
      DCRT Hi-Pot Ramp (DC) 1uA to 3mA 100V to 7kV n/a 3.20%
      ACVB Voltage Break down (AC) 10uA to 5mA 100V to 5kV 50Hz-1kHz 3.00%
      DCVB Voltage Break down (DC) 10uA to 3mA 100V to 7kV n/a 3.20%
      IR Insulation Resistance 1MΩ to 100GΩ 100V to 7kV n/a 1.00%
      SURG Surge Stress 1mVs to 1kVs 100V to 5kV n/a 3.00%
      ILK Leakage Current 1uA to 10mA 1V to 270V 20Hz-1500Hz 0.50%
      VOC Open Circuit Voltage 100mV to 650V 1V to 270V 20Hz-1500Hz 0.10%
      MAGI Magnetizing Current 1mA to 2A 1V to 270V 20Hz-1500Hz 0.10%
      WATT Wattage 1mW to 25W 1V to 270V 20Hz-1500Hz 0.30%
      STRW Stress Wattage 1mW to 25W 1V to 270V 20Hz-1500Hz 1.00%
        DC1000A Tests
      LSBX Inductance with External Bias (Series) 1nH to 1MH 1mV to 5V 20Hz-3MHz 0.05%
      LPBX Inductance with External Bias (Parallel) 1nH to 1MH 1mV to 5V 20Hz-3MHz 0.05%
      ZBX Impedance with External Bias 1mΩ to 1MΩ 1mV to 5V 20Hz-3MHz 0.20%
        AC Interface Fixture Tests
      VOCX O/C Voltage (External Source) 100mV to 650V 1V to 600V 20Hz-5kHz 0.10%
      MAGX Magnetizing Current (External Source) 50mA to 10A 1V to 600V 20Hz-5kHz 0.10%
      WATX Wattage (External Source) 100mW to 6kW 1V to 600V 20Hz-5kHz 1.00%
      STRX Stress Wattage (External Source) 100mW to 6kW 1V to 600V 20Hz-5kHz 1.00%

      User Manual, Software and Firmware

      Please see our Downloads section for the latest full user manual
      Downloads

      Application Notes

      Please see our Technichal Articles section for a wide range of tech notes on testing topics
      Technical articles

      User Foums

      Search our online User Forum for real questions and answers to using the AT Series of testers, and general transformer testing topics.
      Search
      Pedigree
      Software
      Email Voltech
      USA 1-239-437-0494
      EUR 44 1235 861173
      ASIA 44-1235-364-001
      Site Map
      Terms Of Business
      Terms Of Use
      Privacy
      • Terms Of Use
      • Privacy
      • Terms Of Business
      • Site Map
      Contact Voltech
      USA 1-239-437-0494
      EUR 44 1235 861173
      ASIA 44-1235-364-001
      or
      Email Voltech
       
      Submit "Red" = required field
      Please, complete all required fields.
      Please, select country from the list.
      Please, enter a valid Email.
      Thank you for your question. We will reply to your request as soon as possible.
      An error occurred.
      Voltech © 2021
      Voltech on LinkedIn Voltech on YouTube Voltech on Twitter
      We have placed cookies on your computer to help make this website better.
      Please read our Privacy Statement for further information. Otherwise, we'll assume you're OK to continue.
      OK, Don't Show This Message Again