Voltech logo
    • Login
  • Welcome
  • Applications
  • Products
  • Support
  • Contact Us
Voltech logo
  • Welcome
  • Applications
  • Products
  • Support
  • Contact Us
Contact Voltech
USA 1-239-437-0494
EUR 44 1235 861173
ASIA 44-1235-364-001
or
Email Voltech
Voltech on LinkedIn Voltech on YouTube Voltech on Twitter
    • Login
Technical Document Reader
Document
098-100
Name

DC1000 User Manual

Description
The DC1000 user manual.
DC1000 User Manual
Back
to Index
Skip Navigation Links.
Expand 1 Introduction1 Introduction
Expand 2 Getting Started2 Getting Started
Collapse 3 Using the DC10003 Using the DC1000
3.1 With an LCR Meter
3.2 Multiple DC1000S in Parallel
3.3 PC Control of DC1000
3.4 PC Control of DC1000 with RS232 LCR Meter
3.5 PC Control of DC1000 with LEEE LCR Meter
Collapse 3.6 With a Voltech AT3600 or ATI3.6 With a Voltech AT3600 or ATI
3.6.1 Set Up
3.6.2 AT Compensation with Multiple DC1000s
3.6.3 Using IR ILK HPDC HPAC Tests
3.6.4 Using SURG MAGI STRW WATT VOC Tests
3.6.5 LSBX - Inductance with Ext. Bias (Series)
3.6.6 LPBX - Inductance with Ext. Bias (Parallel)
3.6.7 ZBX - Impedance with Ext. Bias
4 RS232 Communication
5 Calibration
Expand 6 PC Software6 PC Software
7 Specifications

3.6 Using the DC1000 with a Voltech AT3600 or ATi (and Optional PC)

3.6.1 Set Up


Fig. 9

Connect the Auxiliary port on your Voltech ATi or AT3600 to the RS232 IN port on your DC1000 using the 9-way male to 9-way female straight-through RS232 cable that was provided with your DC1000.

NOTE: See the RS232 communications section for information on USB to RS232 converters.

If you wish to use a PC to control your AT36 when you have a DC1000 hooked up to the auxiliary port, attach the PC's RS232 connector to the DC1000's RS232 OUT port using the 9-way male to 9-way male straight-through RS232 cable that was provided with your AT product. This setup will work with any communications software you use (e.g. Voltech AT Editor Software, or Voltech DC1000 PC Software).

When using the DC1000 PC Software, which was provided with your DC1000, the HI side of the DC1000 output, and of the inductor under test, should be connected to node 15 of the AT fixture being used, and the LO side should be connected to node 13. There are standard fixtures available from Voltech that provide connection to these nodes, for example the LCR Fixture (VPN 91-227). See the “Fixtures” chapter of your AT manual for information regarding standard, and custom, fixture solutions.

To use any Voltech software with an AT series product, specific DC1000 tests (LPBX, LSBX, and ZBX) must be installed on the AT being used. As with all Voltech AT tests, these are provided on a per AT basis – so no matter how many DC1000s you have connected, one test purchase will cover all DC1000s attached to your AT. Contact your local Voltech supplier for details on attaining these tests.

Prev Next
Email Voltech
USA 1-239-437-0494
EUR 44 1235 861173
ASIA 44-1235-364-001
Site Map
Terms Of Business
Terms Of Use
Privacy
  • Terms Of Use
  • Privacy
  • Terms Of Business
  • Site Map
Contact Voltech
USA 1-239-437-0494
EUR 44 1235 861173
ASIA 44-1235-364-001
or
Email Voltech
 
Submit "Red" = required field
Please, complete all required fields.
Please, select country from the list.
Please, enter a valid Email.
Thank you for your question. We will reply to your request as soon as possible.
An error occurred.
Voltech © 2021
Voltech on LinkedIn Voltech on YouTube Voltech on Twitter
We have placed cookies on your computer to help make this website better.
Please read our Privacy Statement for further information. Otherwise, we'll assume you're OK to continue.
OK, Don't Show This Message Again