Voltech logo
    • Login
  • Welcome
  • Applications
  • Products
  • Support
  • Contact Us
Voltech logo
  • Welcome
  • Applications
  • Products
  • Support
  • Contact Us
Contact Voltech
USA 1-239-437-0494
EUR 44 1235 861173
ASIA 44-1235-364-001
or
Email Voltech
Voltech on LinkedIn Voltech on YouTube Voltech on Twitter
    • Login
Technical Document Reader
Document
098-024
Name

AT3600 User Manual

Description
The full user manual for the AT3600 transformer tester.
AT3600 User Manual
Back
to Index
Skip Navigation Links.
Expand 1 Introduction1 Introduction
Expand 2 Getting Started2 Getting Started
Expand 3 Test Program Editor3 Test Program Editor
Expand 4 Using the Server4 Using the Server
Expand 5 Fixtures5 Fixtures
Collapse 6 Front Panel Operation6 Front Panel Operation
Expand 6.1 Introduction6.1 Introduction
6.2 Self Test
Expand 6.3 Execute Mode6.3 Execute Mode
6.4 Fixture Compensation
Collapse 6.5 Measure Mode6.5 Measure Mode
6.5.1 Measure Mode Operation
6.5.2 Front Panel Measure Mode Error Messages
Expand 6.6 Program Mode6.6 Program Mode
Expand 7 Tests and Test Conditions7 Tests and Test Conditions
Expand 8 Specification8 Specification
Expand 9 Warranty and Service9 Warranty and Service
Expand 10 Safety Systems10 Safety Systems

6.5.2 Front Panel Measure Mode Error Messages

The measurement conditions displayed on the front panel are the actual values of the voltage/current and frequency sensed at the AT3600’s nodes. If voltage or current and frequency test conditions have been specified it may not be possible for the AT to maintain these conditions. For example, if the AC impedance of the winding under test is only 0.1Ω at the specified frequency and you have specified a 5V test signal, then the AT would have to supply 5V / 0.1Ω = 50 Amps!

You will then see a warning similar to this:

The AT will continue to measure accurately, but you can also allow the tester to automatically choose a test voltage or current based on the programmed frequency by selecting AUTO V.

For the leakage inductance test only, AUTO A may be displayed.

Some tests energize more than one winding (e.g. TRL), and in this case, the display will show voltage from the first energized node unless the error is only on the second, when that voltage will be displayed.

For over-range errors you may also see an error message similar to this:

In this case, choose AUTO conditions where possible in a NEW SET UP and consult Chapter 7, Tests and Test Conditions. For low voltage / low power tests only, the tester will continue to try making measurements.

For low power tests that include dc bias you may see the following message:

In which case, you should reduce the dc bias level until this message no longer appears.

Prev Next
Email Voltech
USA 1-239-437-0494
EUR 44 1235 861173
ASIA 44-1235-364-001
Site Map
Terms Of Business
Terms Of Use
Privacy
  • Terms Of Use
  • Privacy
  • Terms Of Business
  • Site Map
Contact Voltech
USA 1-239-437-0494
EUR 44 1235 861173
ASIA 44-1235-364-001
or
Email Voltech
 
Submit "Red" = required field
Please, complete all required fields.
Please, select country from the list.
Please, enter a valid Email.
Thank you for your question. We will reply to your request as soon as possible.
An error occurred.
Voltech © 2021
Voltech on LinkedIn Voltech on YouTube Voltech on Twitter
We have placed cookies on your computer to help make this website better.
Please read our Privacy Statement for further information. Otherwise, we'll assume you're OK to continue.
OK, Don't Show This Message Again