R - Resistance R is the direct current, (DC) resistance offered by an inductor due to the resistance of the winding. This checks that the correct wire has been wound.
VOC - Voltage Open Circuit 1V to 270V@ 20Hz to 1.5KHz This test applies a voltage to the primary and reads the voltage induced in the secondary winding. This checks both the turns ratio and polarity of the windings are correct.
IR - Insulation Resistance 100V to 7KV@ DC Resistance tests are designed to check for poor shielding and insulation between windings.
MAGI - Magnetizing Current 1V to 270V@ 20Hz to 1.5KHz Magnetizing current is the combination of the current required to magnetize the core and the current required to supply the losses in the core.
STRW - Stress Watts 1V to 270V@ to 1.5KHz At a no load and with the secondary open circuit a transformer will still draw current which is proportional to the core losses (eddy currents and hysterisis). Faraday's law suggests that providing the voltage and frequency is increased proportionally core losses should remain the same. Therefore if a dramatic power increase is detected it would indicate a winding fault.
HPAC - High Pot AC 100V to 5.5KV@ 50Hz to 1KHz Hi-pot AC tests are isolation safety tests, which test the isolation between windings and between winding and core, winding to shield.
|