CTY - Continuity Continuity is a test designed to ensure that the transformer is correctly seated in its fixture and that all winding termination is good.
R - Resistance R is the direct current, (DC) resistance offered by an inductor due to the resistance of the winding. This checks that the correct wire has been wound.
LS - Series Inductance 1mV to 5V @ 20Hz to 3MHz Ensures the correct core material has been used and that the number of turns is correct. Range 1nH to 1MH
QL - Quality Factor 1mV to 5V @ 20Hz to 3MHz Ensures that core material and its assembly is correct. Unit of measurement, Q. Range 0.001 to 1000
ANGL - Angle of impedance 1mV to 5V @ 20Hz to 3MHz Ensures that the core material, wire resistance, number of turns and inter-winding capacitance combine to meet design specifications. Unit of measurement: Degrees. Range -360° to +360°
LL - Leakage inductance 1mV to 5V @ 20Hz to 3MHz Ensures that windings are positioned correctly on the bobbin and that any air gap included in the core design is the correct size. Range 1nH to 1kH
C - Inter-winding capacitance 1mV to 5V @ 20Hz to 3MHz Ensures that the insulation thickness between windings is correct. Range 100fF to 1mF
TR - Turns Ratio 1mV to 5V @ 20Hz to 3MHz Ensures that the number of turns on each winding and the winding polarity meet specification.
IR - Insulation Resistance 100V to 7KV@ DC Resistance tests are designed to check for poor shielding and insulation between windings.
HPAC - High Pot AC 100V to 5.5KV@ 50Hz to 1KHz Hi-pot AC tests are isolation safety tests, which test the isolation between windings and between winding and core, winding to shield.
|