The World Leader in Power Analyzers and Transformer Testers
Superior by design, the AT3600, with its patented digital measurement techniques, has revolutionized transformer testing throughout the world. Only the AT3600 combines high and low voltage testing in one station to provide this combination of speed, accuracy, flexibility and reliability.
Overview
The AT3600 is the most cost-effective solution for all transformer and wound component testing requirements.
Using techniques patented by Voltech. The AT3600 introduces a fast, reliable and flexible test solution for all small to medium size wound components. Offering 100% testing of production output for 100% of the required functional and safety test, the AT3600 provides complete assurance of zero-defect components. Whether used for testing manually or with automatic handling systems, the AT3600 will guarantee output quality, minimize test times and reduce costs
The unique design of the AT3600 integrates different test single sources, measuring circuits and a 20-node connection matrix together with a versatile fixture system to bring you benefits that no other instrument can offer.
* International patents: UK 2261957B, Europe
0621953B, USA US5500598
AT3600 - THE automatic transformer tester is
the solution for all your transformer testing
needs.
Click on a solution to learn more...
In addition to the following accessories, the AT3600 can be fitted with a variety of Fixtures, either custom or standard.

AC Interface Fixture

Extend the range of wound components that may be tested by the at 3600

PC Cables

Used to connect your AT series transformer tester’s auxiliary part to a PC running the AT Editor software.

Transit case

This high-quality, durable case will provide years of protection during movement and shipment of your AT3600. Comes with custom cut foam inserts.

Footswitch

Minimize user fatigue, and increase efficiency with this footswitch to start each test process.

Safety light curtain

Protect operators and reduce fatigue with this safely light curtain.

Leadsets

A range of leads and connectors for easy connection to your AT3600.

Test
Description
Main Application
Winding Tested
Reason for Test
Continuity
All transformers
Properly installed fixture
DC Resistance
All transformers
All windings
Properly installed fixture Correct wire used Integrity of terminations
Inductance (Series circuit)
Most transformers But usually not line frequency transformers
One winding usually the primary
Correct primary turns Right grade of core material Core correctly assembled
Inductance (Parallel circuit)
Quality Factor
Right grade of core material Core correctly assembled Check for shorted turns
Equivalent Series Resistance
Equivalent Parallel Resistance
Dissipation Factor
Leakage Inductance
SMPS transformers Communication transformers Other as applicable
Select windings
Check windings have been installed in the correct position relative to the core
Interwinding capacitance
High frequency transformers Isolating transformers
Check winding positioning Check insulation thickness between windings
Turn Ratio and Phasing
Most transformers, but usually not line frequency transformers
All winding
Check winding has correct turns and phasing
Turn Ratio by Inductance
As with Turns Ratio but used where three is poor flux linkage between windings.
All windings
Check windings have correct turns and phasing
Magnestising Current
Usually line frequency transformers
One winding usually the primary
Correct primary turns Correct core material properly assembled
MAGI (External Source)
Open Circuit Voltage
All other windings
Correct Secondary turns Correct phasing
VOCX (External Source)
Insulating Resistance
All transformers
Between selected windings
Winding isolation check where safety is not involved
Hi-Pot (DC)
All transformers especially those used for safety insulation
Between selected windings usually primary or secondary, screen and core
High voltage safety insulation
Hi-Pot (AC)
Inductance with Bias Current(Series Circuit)
Transformers for use in application passing significant dc bias current is part of the normal operat
One winding
Correct number of turns Right grade of core material
Inductance with Bias Current (Parallel Circuit)
Wattage
50Hz Iron core transformers
One winding
Correct core material Properly assembled
Wattage (External Source)
50Hz Iron core transformers
One winding
Correct core material Properly assembled
Surge Stress Test
All transformers, especially those using fine wire
Selected winding
To identify shorted turns
Trimming Adjustment
Transformers with variable / trimmable component
To adjust transformer to give specific measured values
Output to User Port
Allows to AT to perform external switching as part of the test program.
DC Resistance Match
SMPS, audio & telecom
All windings
Check matching between windings
Inductance Match
SMPS, audio & telecom
All windings
Check matching between windings
Capacitance Match
SMPS, audio & telecom
All windings
Check correct winding position on bobbin
General Longitudinal Balance
Audio & telecom
Selected windings
Check common mode rejection ration
Longitudinal Balance
Audio & telecom
Select windings
Check common mode rejection ration
Insertion Loss
Audio & Telecom
Selected windings
Checks losses within the transformers
Frequency Response
Audio & Telecom
Selected windings
Checks losses over a range of frequencies
Return Loss
Audio & Telecom
Selected windings
Checks losses returned by transformer
Impedance
Audio & Telecom
Selected windings
Checks impedance at given frequency
Impedance + Bias
Audio & Telecom
Selected windings
Checks impedance at given frequency
Stress Wattage
Line frequency & high frequency
One winding
Checks integrity of inter-turn insulation the magnetic material and joints
STRW (External Source)
Impedance Phase Angle
Audio & telecom
Selected windings
Finds phases shifts between Voltage and Current on a winding
Interwinding Phase
Test Audio & telecom
Selected windings
Measures phases shifts between a pair of windings.
Leakage Current
Medical Application
Between primary and secondary windings
Checks for a common mode current due to capacitance.
Induction with External Bias (Series Circuit)
Wound components that usually carry a significant DC Bias current in normal operation
Selected windings
Checks number of turns, right grade of correctly assembled core material where bias current is greater than LSB test can handle.
Induction with External Bias (Parallel Circuit)
Wound components that usually carry a significant DC Bias current in normal operation
Selected windings
Checks number of turns, right grade of correctly assembled core material where bias current is greater than LSB test can handle.
Impedance with External Bias
Audio & Telecom
Selected windings
Checks impedance at a given frequency, while applying a greater bias current than is possible with ZB test.
Hi-Pot Ramp (AC)
All transformers especially those used for safety insulation
Between selected windings usually primary to secondary, screens and core
High voltage safety insulation
Hi-Pot Ramp (DC)
All transformers especially those used for safety insulation
Between selected windings usually primary to secondary, screens and core
High voltage safety insulation
* These tests require the use of one or more Voltech DC1000 Precision DC Bias Current Sources.
Editor Software
Version: 3.26.21    Release Date : May, 2008
Easily design your own test programs for your AT3600 transformer tester
Server Software
Version: 3.24.05    Release Date : May, 2008
Server software for your AT3600 that allows you to store and manage test results
Database Connectivity Software
Version: 2.0.0    Release Date : May, 2008
Easy statistical results analysis of your AT3600 test results presented in real time
AT3600 Firmware
Version: 3.1.6    Release Date : July, 2008
Firmware for your AT3600 transformer tester. Click learn more to see the latest features of this firmware and to download the latest version.
Brochures and Manuals
PM6000 Brochure
1007.12 KB
PM6000 Brochure
1007.12 KB
AT series tests application note
3.34 MB
Fixture Construction Manual
2.22 MB
AC Interface User Manual
885.27 KB
Safety Interlock Cable
1.18 MB
AT3600 User Manual
18.02 MB
AT3600 Brochure
1.65 MB
Quick Start Guides
Application Notes
Turns Ratio Measurements
1 MB
Turns Ratio Measurements
1 MB
Transformer Basics
672 KB
Transformer Basics
672 KB
Database connectivity application note
928 KB
Laminate Transformer Testing
1 MB
Ferrite Transformer Testing
4 MB
Ferrite Transformer Testing
4 MB
HiPot Declaration
433 KB
Shorted Turns Detection
444 KB
Leakage Inductance
1 MB
User Port Operation
2 MB
Relay Matrix
1 MB
Kelvin Connections
1 MB
Server Access Queries
2 MB
Constant Current Testing
751 KB
Telecom / Audio Transformer Testing
402 KB